Morningstar ground fault protection device (GFPD) for all TS-MPPT charge controllers below 150V(min. qty: 1)

Morningstar ground fault protection device (GFPD) Morningstar ground fault protection device (GFPD)
Questions about this product? Contact us:
*
*
*
*
*
Morningstar's Ground Fault Protection Device (GFPD) is an innovation for ground fault detection and interruption
for the photovoltaic (PV) industry. It has greater sensitivity and better isolation while maintaining the bond to earth
ground. Ground fault protection is used in electrical systems to prevent current from following any unintended paths
during a ground fault. Morningstar's GFPD has been designed to meet the ground fault protection requirements of
the US National Electric Code (NEC) for grounded PV systems.

How it works: A GFPD needs to detect any stray current and interrupt (break) the circuit until safe operation can be
restored. A current imbalance between the primary positive and negative PV conductors entering the controller or
inverter may indicate a ground fault condition. Morningstar's GFPD will detect this condition and break the circuit on
both the positive and negative legs. Disconnecting both poles ensures interruption of the ground fault current.

Other ground fault detection/interruption products break the bond to the grounded conductor. When this occurs,
not only is the earth bond compromised, but the battery and DC loads can also be left ungrounded and floating. For
a negatively grounded system this means that the negative side of the battery and loads can float to negative Voc in
relation to ground. Morningstar's GFPD better isolates the array from the battery and loads, while maintaining the
bond to ground.

Key features and benefits

Simple and flexible installation:
  • Side or below flush mounting with coupling hardware included
  • Feedback signal wire harness comes pre-wired
  • Includes fused battery cable for power
  • Compatible with other supplier’s PV controllers and inverters
  • For positive or negative grounded PV systems

Greater sensitivity:
  • More precise than fused ground fault protection
  • Activates starting at 300mA compared to 1A for alternative solutions
  • Sensing device provides consistent, accurate measurement

Maintains the bond to earth ground:
  • Normally grounded components (conductors, controller, battery and DC loads) will not be left floating
  • Avoids problems of other ground fault protection options, which can allow the battery and load to float to PV array voltages in relation to ground

No fuses:
  • Avoids problematic replacements of fuses, which are often unavailable at remote sites
  • Uses high quality breaker switches that continue to operate after ground fault interruptions

Safety features:
  • Breaks the connection to the PV array during a fault condition
  • Leaves the battery and DC loads grounded under all conditions. Alternative ground fault solutions require a warning label on the battery to note that "dangerous voltages are present".
  • Features audible and visual indications
  • Includes push-button test circuit

Better isolation:
  • Disconnects both the positive and negative conductor
  • Completely isolates the ground fault from the controller, battery and loads

Supports both single controller and multiple controller systems:
  • Will only shut off affected controllers while maintaining the system earth bond
  • All loads will continue to operate safely with the battery remaining bonded to the ground
  • Multiple controllers and GFPDs may be added later on an as-needed basis
Open Circuit Voltage (Voc)150
Short Circuit Current (Isc) [A]85
Battery voltage [V]10, 72
Consumption< 0.5W
Ambient temperature [C]-40 to +50
ProtectionReverse polarity
CertificationsCE, RoHS, REACH, UL 1741, CSA C22.2 no. 107.1-01
Note (1)Number of poles: 2
Note (2)Trip method: relay
Note (3)Output trip signal: 12V
Note (4)Wire size: #6 AWG (13 mm² )
Width [cm]12.8
Height [cm]26.9
Depth [cm]11.2
Weight [kg]2
Warranty [years]5 years